Computer
| The
data acquisition system is Pentium (133) PC based. The PC is outfitted with a Keithley
Metrabyte DAS 1402 and one EXP 1600 expansion module. The PC runs Labtech Notebookpro and
PCAnywhere software packages for data collection and remote control. Currently the system
is configured to continuously monitor and record summary statistics on all transducers.
This allows for the long term monitoring of both the site conditions and transducer
performance. When predetermined threshold values are exceeded the monitoring mode is
temporarily shut down and a 10-minute "trigger" run is performed. Each trigger
run samples all channels at 25 Hz (we are using 4 pole Bessel filters set at 10 Hz).
Before and after each trigger run a one-minute shunt calibration on all of the pressure
sensors is performed. During these calibration runs, any water that has been collected at
the water collection points (applicable to roof transducers) is drained. |
Back To Top